Appendix

Data Message Example

Example data message:

{
  "ts": 1608416763.9,
  "ambient": 25.83,
  "current1": 0.16,
  "angle": 1.7,
  "pitch": -0.9,
  "motion": 24,
  "wifi_ip": "192.168.1.178",
  "deviceid": "BD6AEDJQ2",
  "vreg": 8.98,
  "vsys": 4.09,
  "vbat": 0,
  "wifi_rssi": -32,
  "light": 1,
  "accel_x": 0.02,
  "accel_y": -0.03,
  "accel_z": -1.01,
  "events": [
    {
      "msg": "Low",
      "topic": "pitch",
      "lv": 30
    }
  ],
  "pressure": 101.26,
  "vin": 12.11,
  "analog1": 0,
  "roll": -1.5,
  "can1": [
    {
      "data": "42C8590803FFD908",
      "id": 419371762
    },
    {
      "data": "4DE9BD3404AA7D34",
      "id": 419372018
    }
  ]
}

List of Data Keys

Key

Description

Units

vsys

Internal system voltage

Volts

vin

Input supply voltage

Volts

vbat

AA Battery Voltage

Volts

tamper

Light sensor tamper status (0 or 1)

gps_lat

GPS Latitude

gps_lon

GPS Longitude

gps_speed

GPS Speed

km/h

ambient

Ambient Temperature

degrees C

capture1

Serial 1 Capture

pitch

Pitch of device

degrees

roll

Roll of device

degrees

angle

Angle of device

degrees

motion

Motion/Vibration

millig-g

analog1

Analog Input 1

analog2

Analog Input 2

analog3

Analog Input 3

analog4

Analog Input 4

analog5

Analog Input 5

digital1

Digital Input 1

digital2

Digital Input 2

digital3

Digital Input 3

digital4

Digital Input 4

digital5

Digital Input 5

tc1

Thermocouple Input 1

degrees C

freq1

Frequency Input 1

Hz

duty1

Duty Cycle Input 1

%

pulse1

Pulse Count Input 1

current1

Current Loop Input 1

current2

Current Loop Input 2

mod1

Modbus Channel 1

mod2

Modbus Channel 2

mod3

Modbus Channel 3

mod4

Modbus Channel 4

mod5

Modbus Channel 5

mod6

Modbus Channel 6

mod7

Modbus Channel 7

mod8

Modbus Channel 8

mod9

Modbus Channel 9

mod10

Modbus Channel 10

can1

CANbus Channel 1

can2

CANbus Channel 2

state

Current device state (0 to 6)

state1_hrs

Number of hours in device state 1

state2_hrs

Number of hours in device state 2

state3_hrs

Number of hours in device state 3

state4_hrs

Number of hours in device state 4

state5_hrs

Number of hours in device state 5

state6_hrs

Number of hours in device state 6

gsm_iccid

ICCID of SIM card

gsm_imei

IMEI of device

gsm_carrier

The mobile carrier

List of Configuration Keys

Type

Key

Name

Description

Range

Units

Notes

string

device.id

Device ID

Unique device serial number.

readonly

string

device.model

Device Model

The device model number.

readonly

string

device.fw

Firmware Version

The device firmware revision.

readonly

string

device.hw

Hardware Revision

The device hardware revision.

readonly

string

device.name

Device Name

A name for the device that is meaningful to the user.

integer

device.base_interval

Base Interval

The time after which the device will wakeup to check which measurements need to be taken and if a transmission is scheduled.

1 to 86400

Seconds

integer

device.transmit_interval

Transmit Interval

The number of base intervals after which a transmission is made.

1 to 1000

integer

device.exception_interval

Exception Interval

If a warning or alarm is active, this setting overrides the Transmit Interval, allowing an increased rate of transmission.

1 to 1000

boolean

device.always_on

Device Always On

If enabled the device will not sleep between Base Intervals and will remain awake. Not recommended for battery powered applications.

boolean

device.batch_tx_enable

Batch Transmit

If enabled, all measurements at the Base Interval will be stored and transmitted at the Transmit Interval. Useful for low power optimisation.

boolean

device.web_always_on

Web Server

This setting will keep the device webserver on all the time (while device is awake). Normally the websever is only available in setup mode.

boolean

device.vin.alert_enable

Power Loss Alert

Sends and alert when voltage on the power input is below a fixed threshold.

boolean

device.vin.sleep_enable

Hibernate on Power Loss

Puts the device into a low power state, when the power input is below a fixed threshold. The device will run off it’s internal backup battery and report periodically.

integer

device.vin.sleep_delay

Hibernate Delay Intervals

The number of base intervals to wait after power loss before entering hibernate mode.

0 to 1000

boolean

device.vin.count_hours

Count Hours

Counts the number of hours the power input is active. Typically used as an engine hour meter when powered from ignition.

boolean

device.batt.alert_enable

AA Battery Low Alert

Enable if an alert is to be sent when the AA battery level drops below a specified limit.

decimal

device.batt.threshold

Threshold

The lower threshold at which an alert is raised.

Volts

boolean

wifi.sta.enable

Wifi

Connect to existing Wifi connection specified below.

string

wifi.sta.ssid

SSID

Wifi SSID to connect to.

password

wifi.sta.pass

Password

Wifi password to use for connection.

string

wifi.sta.ip

Static IP Address

Leave blank if assigned by DHCP.

string

wifi.sta.netmask

Static Netmask

Leave blank if assigned by DHCP.

string

wifi.sta.gw

Static Gateway

Leave blank if assigned by DHCP.

string

wifi.sta.nameserver

DNS Server

Leave blank if assigned by DHCP.

boolean

gsm.enable

4G LTE

Enable the 4G LTE connection.

string

gsm.apn

APN

Access Point Name of mobile operator

string

gsm.user

Username

Username for data connection. Leave blank if not specified

string

gsm.pass

Password

Password for data connection. Leave blank if not specified

string

tamper.name

Name

A name for the light sensor that is meaningful to the user.

boolean

tamper.enable

Tamper Alert

This parameter determines if an alert is generated when the light sensor detects light or not.

string

ambient.name

Name

A name for the input that is meaningful to the user.

integer

ambient.interval

Interval

The number of base intervals after which the temperature is sampled. A value of 1 means that the input is collected every base interval. Set to 0 to disable.

0 to 10000

decimal

ambient.hysteresis

Hysteresis

The amount by which the measured value has to drop below the threshold to re-enable the alert after an event.

0 to 100

°C

string

ambient.warning

Warning

Warning thresholds. Refer to user guide.

-40 to 100

°C

string

ambient.alarm

Alarm

Alarm thresholds. Refer to user guide.

-40 to 100

°C

string

accel.name

Name

A name for the input that is meaningful to the user.

integer

accel.interval

Interval

The number of base intervals after which the accelerometer is sampled. A value of 1 means that the input is collected every base interval. Set to 0 to disable.

0 to 10000

boolean

accel.outputxyz

Output XYZ Vectors

Send X,Y,Z gravity vectors in data output.

decimal

accel.hysteresis

Hysteresis

The amount by which the pitch, roll or angle has to exceed a threshold before triggering alarms or warnings.

0 to 20

Degrees

string

accel.pitch.warning

Pitch Warning

Warning thresholds. Refer to user guide.

-90 to 90

Degrees

string

accel.pitch.alarm

Pitch Alarm

Alarm thresholds. Refer to user guide.

-90 to 90

Degrees

string

accel.roll.warning

Roll Warning

Warning thresholds. Refer to user guide.

-90 to 90

Degrees

string

accel.roll.alarm

Roll Alarm

Alarm thresholds. Refer to user guide.

-90 to 90

Degrees

string

accel.angle.warning

Angle Warning

Warning thresholds. Refer to user guide.

0 to 90

Degrees

string

accel.angle.alarm

Angle Alarm

Alarm thresholds. Refer to user guide.

0 to 90

Degrees

string

accel.motion.warning

Vibration Warning

Warning thresholds. Refer to user guide.

0 to 5000

milli-g

string

accel.motion.alarm

Vibration Alarm

Alarm thresholds. Refer to user guide.

0 to 5000

milli-g

boolean

accel.motion.wake_from_hibernate

Wake from Hibernate

The high warning vibration threshold is used to wake the device when hibernating.

decimal

accel.motion.wake_threshold

Vibration Wake Threshold

The vibration threshold above which the device will wake from hibernation.

1 to 2000

milli-g

boolean

accel.motion.count_hours

Count Vibration Hours

Counts the number of hours the device exceeds the Vibration Wake Threshold. Typically used as an machinery work vs idle hour meter.

string

ble.name

Name

A name that is meaningful to the user.

string

ble.addr

Address

The Bluetooth Address of this device.

readonly

integer

ble.interval

Interval

The number of base intervals at which the Bluetooth module is turned on. Set to 0 to disable.

0 to 10000

integer

ble.scan_time

Scan Time

How long to scan for Bluetooth advertisements each interval.

1 to 300

Seconds

string

ble.id_list

Address Capture List

List of addresses to be captured in HEX format, separated by a comma eg: AC233F6925AD. Leave blank to capture all.

boolean

ble.send_data

Send Raw Data

Send all captured data in the standard data message. If unticked, data is only delivered to the scripting handler.

string

gps.name

Name

A name for the GPS signal that is meaningful to the user.

integer

gps.interval

Interval

The number of base intervals after which the gps is sampled. A value of 1 means that the input is collected every base interval. Set to 0 to disable.

0 to 10000

integer

gps.maxtime

Max Time

Maximum time the device will wait for a valid GPS fix.

0 to 3600

Seconds

boolean

gps.position.alert.enable

Position Alert

Sets whether a change in position generates an alert.

integer

gps.position.alert.radius

Radius

An alert will be raised if the device moves further than this value from the expected position.

1 to 10000

Meters

integer

gps.position.alert.hysteresis

Hysteresis

Once the alert is active or inactive, the radius must change by this value to change the alert state.

1 to 10000

Meters

decimal

gps.position.alert.lat

Expected Latitude

Latitude at which the device is expected to be.

-90 to 90

Degrees

decimal

gps.position.alert.lon

Expected Longitude

Longitude at which the device is expected to be.

-180 to 180

Degrees

boolean

gps.speed.count_hours

Count Movement Hours

Counts the number of hours the device is moving according to the GPS speed.

boolean

gps.speed.alert.enable

Speed Alert

Sets whether a change in speed generates an alert.

integer

gps.speed.alert.threshold

Threshold

An alert will be raised if the device’s speed goes above this threshold.

1 to 1000

km/h

integer

gps.speed.alert.hysteresis

Hysteresis

Once the alert is active or inactive, the speed must change by this value to change the alert state.

1 to 1000

km/h

string

input1.name

Name

A name for the input that is meaningful to the user.

integer

input1.interval

Interval

The number of base intervals after which the input is sampled. A value of 1 means that the input is collected every base interval. Set to 0 to disable.

0 to 10000

preset

input1.mode

Mode

Specifies the function of the IN1 terminal. The calibration, warnings and alarms are applied to this mode.

Digital,Analog,Frequency,Duty Cycle

decimal

input1.digital.threshold

Digital Threshold

A threshold against which the input is compared to determine if the input state is ON or OFF.

0 to 30

Volts

decimal

input1.digital.hysteresis

Digital Hysteresis

Once the input is in a certain state, hysteresis is the amount by which the input has to change before moving to the other state.

0 to 20

Volts

boolean

input1.digital.count_hours

Count Hours

Counts the number of hours the digtial input is ON (above threshold).

boolean

input1.digital.alert.enable

Digital Change Alert

Sets whether a change in digital state generates an alert.

string

input1.cal

Analog 1 Calibration

Calibration parameters for Analog 1. Refer to user guide.

string

input1.unit

Unit

The unit of measure associated with the calibration. Eg: Litres, RPM

string

input1.warning

Warning

Warning thresholds. Refer to user guide.

string

input1.alarm

Alarm

Alarm thresholds. Refer to user guide.

decimal

input1.hysteresis

Alarm/Warning Hysteresis

Once the input is in a certain state, hysteresis is the amount by which the input has to change before moving to the other state.

boolean

input1.pulse.enable

Pulse Counting

Enables counting of pulses in addition to frequency measurement.

integer

input1.pulse.reset_value

Reset Value

The value at which the number of pulses counted on the input is reset to zero.

1 to 2000000000

Counts

decimal

input1.pulse.scaling

Pulse Scaling

Multiplier to convert the pulse count to a useful unit.

string

input1.pulse.unit

Pulse Unit

The unit of measure associated with the scaled pulse count. Eg: Litres

string

input1.pulse.warning

Pulse Warning

Warning thresholds. Refer to user guide.

string

input1.pulse.alarm

Pulse Alarm

Alarm thresholds. Refer to user guide.

string

input2.name

Name

A name for the input that is meaningful to the user.

integer

input2.interval

Interval

The number of base intervals after which the input is sampled. A value of 1 means that the input is collected every base interval. Set to 0 to disable.

0 to 10000

preset

input2.mode

Mode

Specifies the function of the IN2 terminal. The calibration, warnings and alarms are applied to this mode.

Digital,Analog

decimal

input2.digital.threshold

Digital Threshold

A threshold against which the input is compared to determine if the input state is ON or OFF.

0 to 30

Volts

decimal

input2.digital.hysteresis

Digital Hysteresis

Once the input is in a certain state, hysteresis is the amount by which the input has to change before moving to the other state.

0 to 20

Volts

boolean

input2.digital.count_hours

Count Hours

Counts the number of hours the digtial input is ON (above threshold).

boolean

input2.digital.alert.enable

Digital Change Alert

Sets whether a change in digital state generates an alert.

string

input2.cal

Analog 2 Calibration

Calibration parameters for Analog 2. Refer to user guide.

string

input2.unit

Unit

The unit of measure associated with the calibration. Eg: Litres, RPM, Volts

string

input2.warning

Warning

Warning thresholds. Refer to user guide.

string

input2.alarm

Alarm

Alarm thresholds. Refer to user guide.

decimal

input2.hysteresis

Alarm/Warning Hysteresis

Once the input is in a certain state, hysteresis is the amount by which the input has to change before moving to the other state.

string

output1.name

Name

A name for the input that is meaningful to the user.

integer

output1.interval

Interval

Does not affect output mode. The number of base intervals at which the input is sampled. Set to 0 to disable. Set to 1 for every base interval.

0 to 10000

preset

output1.mode

Mode

Specifies the function of the OUT1 terminal.

Output,Digital,Analog

boolean

output1.warnings

Warnings

Determines if the output is turned on when a warning is active.

boolean

output1.alarms

Alarms

Determines if the output is turned on when an alarm is active.

boolean

output1.alerts

Alerts

Determines if the output is turned on when an alert is active.

integer

output1.hold_time

Hold Time

Sets the time in seconds for which the output is held on after it is triggered. If set to zero, the output remains on while any exceptions are active.

Seconds

boolean

output1.digital.alert.enable

Digital Change Alert

If enabled, a change in digital state will generate an alert.

string

output1.cal

Analog 3 Calibration

Calibration parameters for Analog 3. Refer to user guide.

string

output1.unit

Unit

The unit of measure associated with the calibration. Examples: Litres, RPM, Volts

string

output1.warning

Warning

Warning thresholds. Refer to user guide.

string

output1.alarm

Alarm

Alarm thresholds. Refer to user guide.

decimal

output1.hysteresis

Alarm/Warning Hysteresis

Once the input is in a certain state, hysteresis is the amount by which the input has to change before moving to the other state.

string

tc1.name

Name

A name for the input that is meaningful to the user.

integer

tc1.interval

Interval

The number of base intervals after which the thermocouple is measured and events are checked. A value of 1 means that the input is collected every base interval. Set to 0 to disable.

0 to 10000

decimal

tc1.hysteresis

Hysteresis

The amount by which the measured value has to drop below the threshold to re-enable the event.

-1000 to 1000

°C

string

tc1.type

Type

Determines the type of thermocouple connected. Valid values are: K, J, T, N, S, E, B and R

string

tc1.warning

Warning

Warning thresholds. Refer to user guide.

-1000 to 1000

°C

string

tc1.alarm

Alarm

Alarm thresholds. Refer to user guide.

-1000 to 1000

°C

string

can1.name

Name

A name that is meaningful to the user.

integer

can1.interval

Interval

The number of base intervals after which the CAN module is turned on. Set to 0 to disable.

0 to 10000

integer

can1.nominal_baud

Nominal Baud Rate

Baud rate for CAN communication. Supported values are: 125, 250, 500, 1000

kbit/s

integer

can1.capture_time

Capture Time

The device will capture matching messages for this length of time.

Seconds

boolean

can1.tx_enable

TX Enable

Allows the device to transmit and acknowledge messages on the CAN bus.

string

can1.id_list

ID Capture List

List of IDs to be captured in HEX format, separated by a comma eg: 18FEE60A. Leave blank to capture all.

boolean

can1.send_data

Send Raw Data

Send all captured data in the standard data message. If unticked, data is only delivered to the scripting handler.

string

can2.name

Name

A name that is meaningful to the user.

integer

can2.interval

Interval

The number of base intervals after which the CAN module is turned on. Set to 0 to disable.

0 to 10000

integer

can2.nominal_baud

Nominal Baud Rate

Baud rate for CAN communication. Supported values are: 125, 250, 500, 1000

kbit/s

integer

can2.capture_time

Capture Time

The device will capture matching messages for this length of time.

Seconds

boolean

can2.tx_enable

TX Enable

Allows the device to transmit and acknowledge messages on the CAN bus.

string

can2.id_list

ID Capture List

List of IDs to be captured in HEX format, separated by a comma eg: 18FEE60A. Leave blank to capture all.

boolean

can2.send_data

Send Raw Data

Send all captured data in the standard data message. If unticked, data is only delivered to the scripting handler.

string

current1.name

Name

A name for the input that is meaningful to the user.

integer

current1.interval

Interval

The number of base intervals after which the input is sampled. A value of 1 means that the input is collected every base interval. Set to 0 to disable.

0 to 10000

preset

current1.mode

Mode

Specifies the function of the SRC1 terminal.

Current,Digital

boolean

current1.always_on

Always On

Determines if Switched Power is to be enabled permanently.

decimal

current1.start_time

Start Time

Time in seconds that the output is turned on before measurements are taken. Allows an external device to stabilise.

0 to 3600

Seconds

boolean

current1.digital.alert.enable

Digital Change Alert

Sets whether a change in digital state generates an alert. (Digital Mode Only)

string

current1.cal

Current 1 Calibration

Calibration parameters for Current 1. Refer to user guide.

string

current1.unit

Unit

The unit of measure associated with the calibration. Eg: Percent, Litres

string

current1.warning

Warning

Warning thresholds. Refer to user guide.

string

current1.alarm

Alarm

Alarm thresholds. Refer to user guide.

decimal

current1.hysteresis

Alarm/Warning Hysteresis

The amount by which the calibrated current value has to drop below the threshold to re-enable the event.

string

current2.name

Name

A name for the input that is meaningful to the user.

integer

current2.interval

Interval

The number of base intervals after which the input is sampled. A value of 1 means that the input is collected every base interval. Set to 0 to disable.

0 to 10000

preset

current2.mode

Mode

Specifies the function of the SRC2 terminal.

Current,Digital

boolean

current2.always_on

Always On

Determines if Switched Power is to be enabled permanently.

decimal

current2.start_time

Start Time

Time in seconds that the output is turned on before measurements are taken. Allows an external device to stabilise.

0 to 3600

Seconds

boolean

current2.digital.alert.enable

Digital Change Alert

Sets whether a change in digital state generates an alert. (Digital Mode Only)

string

current2.cal

Current 2 Calibration

Calibration parameters for Current 2. Refer to user guide.

string

current2.unit

Unit

The unit of measure associated with the calibration. Eg: Percent, Litres

string

current2.warning

Warning

Warning thresholds. Refer to user guide.

string

current2.alarm

Alarm

Alarm thresholds. Refer to user guide.

decimal

current2.hysteresis

Alarm/Warning Hysteresis

The amount by which the calibrated current value has to drop below the threshold to re-enable the event.

string

serial1.name

Name

A name for the input that is meaningful to the user.

integer

serial1.interval

Interval

The number of base intervals after which the serial port is turned on. Set to 0 to disable.

0 to 10000

preset

serial1.type

Type

The electrical interface type.

RS232,RS485

boolean

serial1.termination

Termination Resistor

This parameter enables the integrated termination resistor.

preset

serial1.mode

Mode

Describes how the serial port is to be handled. CAPTURE: serial data is captured between start and end characters. MODBUS: serial data is treated according to MODBUS RTU standard

Capture,Modbus,Scripted

integer

serial1.baud

Baud Rate

Baud rate for serial communication. Common values are: 4800, 9600, 19200, 38400, 57600, 115200

string

serial1.settings

Settings

A string describing the number of bytes: 7,8,9. Parity type: N(none), E(even), O(odd). Number of stop bits: 1 or 2. Typically: 8N1

string

serial1.capture.start

Start String

The serial port starts reading data when it detects these characters. Example: $GPGGA, serial data will be ignored until $GPGGA is received after which data will be captured. If nothing is specified, the serial port will capture all data until the timeout period is reached.

integer

serial1.capture.start_idle_time

Idle Time Before Start

For a valid start condition, there must be this amount of idle time before receiving serial data. Additionally, the captured data will restarted if the serial port is idle for this time. Set to 0 to disable.

0 to 60000

Milliseconds

string

serial1.capture.end

End String

Once capturing, if these characters are received, the serial port will stop capturing and will return to sleep. For binary data or escape sequences refer to the User Guide.

string

serial1.capture.request

Request String

This string will be sent when the serial port is first turned on. Use this function to request data from a remote module.

integer

serial1.capture.maxtime

Max Time

The device will wait this length of time for a valid capture.

Seconds

integer

serial1.capture.maxchars

Max Chars

Maximum number of characters to be captured before the serial port goes back to sleep.

boolean

serial1.capture.alert

Alert on Capture

If checked an alert will be raised on any successful serial capture.

decimal

serial1.modbus.timeout

Slave Timeout

How long to wait for a response from each slave device.

0 to 10

Seconds

string

mod1.name

Modbus 1 Name

A meaningful name for the measurement.

string

mod1.settings

Modbus 1 Settings

Settings for Modbus Channel 1. Refer to user guide.

string

mod1.cal

Modbus 1 Calibration

Calibration paramters for Modbus Channel 1. Refer to user guide.

string

mod1.unit

Modbus 1 Unit

The unit of measure associated with the calibration.

string

mod1.warning

Warning

Warning thresholds. Refer to user guide.

string

mod1.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod2.name

Modbus 2 Name

A meaningful name for the measurement.

string

mod2.settings

Modbus 2 Settings

Settings for Modbus Channel 2. Refer to user guide.

string

mod2.cal

Modbus 2 Calibration

Calibration paramters for Modbus Channel 2. Refer to user guide.

string

mod2.unit

Modbus 2 Unit

The unit of measure associated with the calibration.

string

mod2.warning

Warning

Warning thresholds. Refer to user guide.

string

mod2.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod3.name

Modbus 3 Name

A meaningful name for the measurement.

string

mod3.settings

Modbus 3 Settings

Settings for Modbus Channel 3. Refer to user guide.

string

mod3.cal

Modbus 3 Calibration

Calibration paramters for Modbus Channel 3. Refer to user guide.

string

mod3.unit

Modbus 3 Unit

The unit of measure associated with the calibration.

string

mod3.warning

Warning

Warning thresholds. Refer to user guide.

string

mod3.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod4.name

Modbus 4 Name

A meaningful name for the measurement.

string

mod4.settings

Modbus 4 Settings

Settings for Modbus Channel 4. Refer to user guide.

string

mod4.cal

Modbus 4 Calibration

Calibration paramters for Modbus Channel 4. Refer to user guide.

string

mod4.unit

Modbus 4 Unit

The unit of measure associated with the calibration.

string

mod4.warning

Warning

Warning thresholds. Refer to user guide.

string

mod4.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod5.name

Modbus 5 Name

A meaningful name for the measurement.

string

mod5.settings

Modbus 5 Settings

Settings for Modbus Channel 5. Refer to user guide.

string

mod5.cal

Modbus 5 Calibration

Calibration paramters for Modbus Channel 5. Refer to user guide.

string

mod5.unit

Modbus 5 Unit

The unit of measure associated with the calibration.

string

mod5.warning

Warning

Warning thresholds. Refer to user guide.

string

mod5.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod6.name

Modbus 6 Name

A meaningful name for Modbus Channel 6.

string

mod6.settings

Modbus 6 Settings

Settings for Modbus Channel 6. Refer to user guide.

string

mod6.cal

Modbus 6 Calibration

Calibration paramters for Modbus Channel 6. Refer to user guide.

string

mod6.unit

Modbus 6 Unit

The unit of measure associated with the calibration.

string

mod6.warning

Warning

Warning thresholds. Refer to user guide.

string

mod6.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod7.name

Modbus 7 Name

A meaningful name for the measurement.

string

mod7.settings

Modbus 7 Settings

Settings for Modbus Channel 7. Refer to user guide.

string

mod7.cal

Modbus 7 Calibration

Calibration paramters for Modbus Channel 7. Refer to user guide.

string

mod7.unit

Modbus 7 Unit

The unit of measure associated with the calibration.

string

mod7.warning

Warning

Warning thresholds. Refer to user guide.

string

mod7.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod8.name

Modbus 8 Name

A meaningful name for the measurement.

string

mod8.settings

Modbus 8 Settings

Settings for Modbus Channel 8. Refer to user guide.

string

mod8.cal

Modbus 8 Calibration

Calibration paramters for Modbus Channel 8. Refer to user guide.

string

mod8.unit

Modbus 8 Unit

The unit of measure associated with the calibration.

string

mod8.warning

Warning

Warning thresholds. Refer to user guide.

string

mod8.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod9.name

Modbus 9 Name

A meaningful name for the measurement.

string

mod9.settings

Modbus 9 Settings

Settings for Modbus Channel 9. Refer to user guide.

string

mod9.cal

Modbus 9 Calibration

Calibration paramters for Modbus Channel 9. Refer to user guide.

string

mod9.unit

Modbus 9 Unit

The unit of measure associated with the calibration.

string

mod9.warning

Warning

Warning thresholds. Refer to user guide.

string

mod9.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod10.name

Modbus 10 Name

A meaningful name for the measurement.

string

mod10.settings

Modbus 10 Settings

Settings for Modbus Channel 10. Refer to user guide.

string

mod10.cal

Modbus 10 Calibration

Calibration paramters for Modbus Channel 10. Refer to user guide.

string

mod10.unit

Modbus 10 Unit

The unit of measure associated with the calibration.

string

mod10.warning

Warning

Warning thresholds. Refer to user guide.

string

mod10.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod11.name

Modbus 11 Name

A meaningful name for the measurement.

string

mod11.settings

Modbus 11 Settings

Settings for Modbus Channel 11. Refer to user guide.

string

mod11.cal

Modbus 11 Calibration

Calibration paramters for Modbus Channel 11. Refer to user guide.

string

mod11.unit

Modbus 11 Unit

The unit of measure associated with the calibration.

string

mod11.warning

Warning

Warning thresholds. Refer to user guide.

string

mod11.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod12.name

Modbus 12 Name

A meaningful name for the measurement.

string

mod12.settings

Modbus 12 Settings

Settings for Modbus Channel 12. Refer to user guide.

string

mod12.cal

Modbus 12 Calibration

Calibration paramters for Modbus Channel 12. Refer to user guide.

string

mod12.unit

Modbus 12 Unit

The unit of measure associated with the calibration.

string

mod12.warning

Warning

Warning thresholds. Refer to user guide.

string

mod12.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod13.name

Modbus 13 Name

A meaningful name for the measurement.

string

mod13.settings

Modbus 13 Settings

Settings for Modbus Channel 13. Refer to user guide.

string

mod13.cal

Modbus 13 Calibration

Calibration paramters for Modbus Channel 13. Refer to user guide.

string

mod13.unit

Modbus 13 Unit

The unit of measure associated with the calibration.

string

mod13.warning

Warning

Warning thresholds. Refer to user guide.

string

mod13.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod14.name

Modbus 14 Name

A meaningful name for the measurement.

string

mod14.settings

Modbus 14 Settings

Settings for Modbus Channel 14. Refer to user guide.

string

mod14.cal

Modbus 14 Calibration

Calibration paramters for Modbus Channel 14. Refer to user guide.

string

mod14.unit

Modbus 14 Unit

The unit of measure associated with the calibration.

string

mod14.warning

Warning

Warning thresholds. Refer to user guide.

string

mod14.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod15.name

Modbus 15 Name

A meaningful name for the measurement.

string

mod15.settings

Modbus 15 Settings

Settings for Modbus Channel 15. Refer to user guide.

string

mod15.cal

Modbus 15 Calibration

Calibration paramters for Modbus Channel 15. Refer to user guide.

string

mod15.unit

Modbus 15 Unit

The unit of measure associated with the calibration.

string

mod15.warning

Warning

Warning thresholds. Refer to user guide.

string

mod15.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod16.name

Modbus 16 Name

A meaningful name for Modbus Channel 16.

string

mod16.settings

Modbus 16 Settings

Settings for Modbus Channel 16. Refer to user guide.

string

mod16.cal

Modbus 16 Calibration

Calibration paramters for Modbus Channel 16. Refer to user guide.

string

mod16.unit

Modbus 16 Unit

The unit of measure associated with the calibration.

string

mod16.warning

Warning

Warning thresholds. Refer to user guide.

string

mod16.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod17.name

Modbus 17 Name

A meaningful name for the measurement.

string

mod17.settings

Modbus 17 Settings

Settings for Modbus Channel 17. Refer to user guide.

string

mod17.cal

Modbus 17 Calibration

Calibration paramters for Modbus Channel 17. Refer to user guide.

string

mod17.unit

Modbus 17 Unit

The unit of measure associated with the calibration.

string

mod17.warning

Warning

Warning thresholds. Refer to user guide.

string

mod17.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod18.name

Modbus 18 Name

A meaningful name for the measurement.

string

mod18.settings

Modbus 18 Settings

Settings for Modbus Channel 18. Refer to user guide.

string

mod18.cal

Modbus 18 Calibration

Calibration paramters for Modbus Channel 18. Refer to user guide.

string

mod18.unit

Modbus 18 Unit

The unit of measure associated with the calibration.

string

mod18.warning

Warning

Warning thresholds. Refer to user guide.

string

mod18.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod19.name

Modbus 19 Name

A meaningful name for the measurement.

string

mod19.settings

Modbus 19 Settings

Settings for Modbus Channel 19. Refer to user guide.

string

mod19.cal

Modbus 19 Calibration

Calibration paramters for Modbus Channel 19. Refer to user guide.

string

mod19.unit

Modbus 19 Unit

The unit of measure associated with the calibration.

string

mod19.warning

Warning

Warning thresholds. Refer to user guide.

string

mod19.alarm

Alarm

Alarm thresholds. Refer to user guide.

string

mod20.name

Modbus 20 Name

A meaningful name for the measurement.

string

mod20.settings

Modbus 20 Settings

Settings for Modbus Channel 120. Refer to user guide.

string

mod20.cal

Modbus 20 Calibration

Calibration paramters for Modbus Channel 120. Refer to user guide.

string

mod20.unit

Modbus 20 Unit

The unit of measure associated with the calibration.

string

mod20.warning

Warning

Warning thresholds. Refer to user guide.

string

mod20.alarm

Alarm

Alarm thresholds. Refer to user guide.

boolean

endpoint.config_to_portal

Configuration via Senquip Portal

Enables connection to Senquip Portal for remote configuration.

boolean

endpoint.data_to_portal

Send Data to Senquip Portal

Enables data from the device to be sent to the Senquip Portal.

boolean

endpoint.buffer_enable

Offline Buffer

Save data if device is offline, and send when network is available.

boolean

endpoint.addtimedate

Add Formatted Time

This option adds a human readable time/date format to the data output.

boolean

endpoint.network_report

Report Network Info

Add network details and signal strength to data output.

boolean

endpoint.sq_data_format

Use Senquip Data Format

Automatically send the Senquip data message to the endpoints below (does not affect data to Senquip Portal). If unchecked, no data is sent and the device script should create messages.

boolean

endpoint.udp.enable

UDP

Enables sending data over UDP to specified address below.

string

endpoint.udp.address

UDP Address

Address and port to send data to.

boolean

endpoint.http.enable

HTTP POST

Enables sending data via a HTTP POST request to address below.

string

endpoint.http.address

HTTP Address

Destination address and port for HTTP POST request.

boolean

endpoint.mqtt.enable

MQTT

Enables sending data to a MQTT broker.

string

endpoint.mqtt.server

Broker Address

MQTT Broker Address and Port.

string

endpoint.mqtt.client_id

Client ID

Client ID to send to the broker. Defaults to device.id if left blank.

string

endpoint.mqtt.data_topic

Data Topic

Topic for Senquip formatted data messages. A single ‘?’ character will be replaced with the Device ID. Leave blank for ‘?/data’.

string

endpoint.mqtt.user

Username

Username for MQTT authentication with username/password. (Optional)

string

endpoint.mqtt.pass

Password

Password for MQTT authentication with username/password. (Optional)